Product

Industrial RO Water Treatment System Manufacturer

Compare industrial RO systems, configurations, equipment photos and installation needs. Send water quality and capacity details for a tailored quotation.

Liangpu 1T/h reverse osmosis system with blue pretreatment tanks

Choose an RO System Around Your Water and Production Requirements

Liangpu industrial RO systems are stainless-steel reverse osmosis units with standard models from 0.25 to 10 T/h of treated water, a desalination rate of 95%–99% and a membrane inlet pressure of 0.6–1.0 MPa. The process runs raw water → quartz sand filter → activated carbon filter → antiscalant dosing → cartridge filter → high-pressure pump → RO unit → treated water.

Compare Liangpu reverse osmosis equipment from compact 0.25T models to 10T split-type units, with 12T, 15T and 30T frames and double-stage systems available. Start with your required treated-water output, raw-water analysis and final water use. These determine the pretreatment, membrane arrangement and controls to include in a quotation.

Request a configuration and quotation · See a real 1T equipment example

Standard Models and Dimensions

Model numbers indicate nominal treated-water output per hour. Actual output depends on feed-water quality and temperature, so the quotation states the rated output and the feed-water conditions it is based on. Dimensions below are the manufacturer’s equipment dimensions in millimetres (length × width × height); they are not packing dimensions.

Standard models — dimensions and power supply
Model Configuration Dimensions L × W × H (mm) Power supply
0.25T/h Simple, without tank 530 × 630 × 1506 220 V / 50 Hz
0.25T/h Simple, with tank 930 × 630 × 1506 220 V / 50 Hz
0.5T/h Standard 1200 × 645 × 1715 220 V / 50 Hz
Show all 13 rows (10 more)
Model Configuration Dimensions L × W × H (mm) Power supply
0.5T/h Simple, without tank 680 × 630 × 1506 220 V / 50 Hz
0.5T/h Simple, with tank 1160 × 630 × 1506 220 V / 50 Hz
1T/h Standard 1565 × 700 × 1656 380 V / 50 Hz
2T/h Standard 2500 × 650 × 1665 380 V / 50 Hz
3T/h Standard 2500 × 750 × 1705 380 V / 50 Hz
4T/h Integrated 2650 × 750 × 1767 380 V / 50 Hz
5T/h Integrated 2700 × 925 × 1767 380 V / 50 Hz
6T/h Integrated 2700 × 1000 × 1828 380 V / 50 Hz
8T/h Split type 2800 × 860 × 1600 380 V / 50 Hz
10T/h Split type 2800 × 860 × 1850 380 V / 50 Hz

Power supply is 220 V / 50 Hz for the 0.25T and 0.5T models and 380 V / 50 Hz from 1T upward. Capacities above 10T, double-stage systems and configurations built for another supply are confirmed on the project datasheet. Packing sizes, material options and the final arrangement of each unit are confirmed in the quotation.

Other Configurations in the Same Range

The same range is built in several arrangements: with three pretreatment tanks instead of two, with 4040 or 8040 membrane elements, as an integrated or split-type frame, and with an optional stainless-steel tank. Each has its own footprint, so confirm the arrangement before laying out the site.

Single-stage configurations — dimensions L × W × H (mm)
Model Configuration Dimensions
0.5T/h With 4021 membrane elements 1100 × 550 × 900
1T/h Three-vessel unit, two old-type vessels 1116 × 700 × 1656
1T/h Three-tank 1950 × 700 × 1656
Show all 21 rows (18 more)
Model Configuration Dimensions
1.5T/h Standard 1665 × 700 × 1656
2T/h Three-tank 2950 × 650 × 1665
3T/h Three-tank 3050 × 750 × 1705
3T/h 8040 membranes 2300 × 850 × 1705
3T/h 8040 membranes, three-tank 2850 × 850 × 1705
3T/h Split type, 8040 membranes 1700 × 810 × 1488
4T/h Integrated, three-tank 3270 × 750 × 1767
4T/h Split type, 4040 membranes, half frame 2600 × 780 × 1500
4T/h Split type, 8040 membranes, half frame 2700 × 795 × 1500
4T/h Integrated, 8040 membranes 2650 × 1000 × 1767
4T/h Integrated, 8040 membranes, three-tank 3270 × 1000 × 1767
5T/h Integrated, 8040 membranes 2700 × 1000 × 1767
5T/h Split type, 4040 membranes 2600 × 780 × 1500
6T/h Integrated, three-tank 3290 × 1000 × 1828
6T/h Split type, 8040 membranes 2700 × 860 × 1500
12T/h Split type, half frame 3800 × 900 × 1600
15T/h Split type, half frame 6000 × 1200 × 1650
30T/h Split type, half frame 6000 × 1200 × 2250

Double-Stage Systems

A double-stage system pairs a larger first stage with a smaller second stage, for feed water that needs two passes to reach the required outlet quality. The notation below states the first and second stage capacity, for example front 0.75 T/h with rear 0.5 T/h.

Double-stage configurations — dimensions L × W × H (mm)
System Stages Dimensions
0.5T/h double-stage Front 0.75 / rear 0.5 1725 × 700 × 1656
0.5T/h double-stage, split, three tanks Front 1 / rear 0.5 Main section 1146 × 700 × 1656; tank section 1453 × 340 × 1656
1T/h double-stage Front 1.5 / rear 1 2500 × 600 × 1665
Show all 15 rows (12 more)
System Stages Dimensions
1T/h double-stage, three-tank Front 1.5 / rear 1 2900 × 600 × 1665
1T/h double-stage Front 2 / rear 1 2500 × 650 × 1665
1T/h double-stage Front 3 / rear 1 2380 × 890 × 1705
1T/h double-stage Front 3 / rear 1, 2069 tanks with 8040 membrane housings 2380 × 890 × 1705
2T/h double-stage Front 6 / rear 2, 8040 membranes 2800 × 1000 × 1650
2T/h double-stage Front 3 / rear 2, 4040 membranes 2500 × 900 × 1717
2T/h double-stage Front 3 / rear 2, 8040 membranes 2600 × 930 × 1717
3T/h double-stage Front 4 / rear 3 2800 × 1000 × 1650
4T/h double-stage Front 6 / rear 4, split type 2800 × 1000 × 1850
6T/h double-stage Front 8 / rear 6 2800 × 1500 × 1600
9T/h double-stage Front 12 / rear 9, stainless housings 3800 × 1580 × 1730
15T/h double-stage Front 20 / rear 15 6000 × 2000 × 1700

EDI and Ultrafiltration Units

EDI and ultrafiltration configurations — dimensions L × W × H (mm)
Unit Configuration Dimensions
2T/h EDI Electrodeionisation unit 900 × 700 × 1500
2T/h Split type, 8040 membranes 1700 × 810 × 1488
4T/h Split type, 8040 membranes 1700 × 810 × 1488
Show all 6 rows (3 more)
Unit Configuration Dimensions
5T/h Split type, 8040 membranes 1700 × 860 × 1878
5T/h ultrafiltration Large-membrane unit, 1853 vessel 2300 × 850 × 1705
6T/h ultrafiltration Ultrafiltration unit 1400 × 850 × 1900

Shared Specifications

Specifications common to the standard range
Body and frame Stainless steel
Raw-water pressure 0.1–0.3 MPa
Membrane inlet pressure 0.6–1.0 MPa
Show all 8 rows (5 more)
Desalination rate 95%–99%
Process flow Raw water → quartz-sand filter → carbon filter → antiscalant dosing → precision filter → high-pressure pump → RO main unit → pure water output (a raw-water feed pump is added in configurations that need one)
Optional pump brands Xinjie or Nanfang
Optional membrane brands Huitong or DowDuPont
10T configuration Split-type machine (separate pretreatment section and RO main unit)

Pump and membrane brands are listed by the manufacturer as options and are chosen at quotation stage; they are not included in every configuration by default, and the brand supplied is stated in the quotation. Feed-water analysis determines the pretreatment design, dosing requirement and membrane arrangement.

Equipment Photos by Capacity

Photographs from our production floor, grouped by nominal treated-water output. Every unit is wrapped for shipment before dispatch. Pretreatment vessels carry Chinese shop labels; each photo caption states which filter the vessel is.

0.25T/h

0.25T/h standard unit
0.25T/h standard unit
Photos (11 more)

0.5T/h

0.5T/h standard unit
0.5T/h standard unit

1T/h

1T/h standard unit
1T/h standard unit
More photos (1)
1T/h three-tank unit
1T/h three-tank unit

1.5T/h

1.5T/h standard unit
1.5T/h standard unit

2T/h

2T/h standard unit
2T/h standard unit
More photos (1)
2T/h three-tank unit
2T/h three-tank unit

3T/h

3T/h standard unit
3T/h standard unit

4T/h

4T/h integrated unit
4T/h integrated unit

5T/h

5T/h integrated unit
5T/h integrated unit

Large RO and membrane banks

Large RO unit with membrane banks
Large RO unit with membrane banks

40T/h ultrafiltration

40T/h ultrafiltration unit
40T/h ultrafiltration unit

Choosing Between Integrated and Split-Type

Integrated units arrive on one frame and need a single floor area. Split-type units separate the pretreatment section from the RO main unit, which suits sites where access is narrow or where the two parts are installed in different positions. Compare the dimensions above with the door, lift and stairway clearances on site before ordering.

Read the 4T, 6T and 8T industrial RO selection guide.

What Will Your Quotation Include?

  • Feed-water treatment: the selected filter vessels, media, cartridge filtration and any required dosing or softening.
  • RO assembly: membrane specification, housings, pumps, instruments and control arrangement.
  • Water storage and distribution: whether tanks, delivery pumps and connection fittings are included or supplied separately.
  • Electrical details: confirmed voltage, phase, frequency and connected load for the selected model.
  • Delivery scope: packing method, packing dimensions, accessories, destination and agreed shipping terms.

These are items to confirm in the quotation, not a claim that every option is included as standard.

Water Quality and Performance

Send a recent feed-water analysis and your required outlet-water specification. A useful quotation should state rated treated-water output and the feed-water conditions used to determine it. Ask for the agreed conductivity unit, measurement conditions, recovery and acceptance criteria.

The standard range is rated at a desalination rate of 95%–99%. Suitability for a particular production process must be confirmed against the project requirements.

Installation and Service Planning

  • Provide the available floor area and access dimensions; allow space for maintenance.
  • Confirm feed-water supply, treated-water connections and concentrate/backwash drainage.
  • Tell us your voltage, phase and frequency (e.g. 380 V/50 Hz, 220 V/60 Hz) so the pumps and controls are built for your power supply.
  • Ask which installation instructions, commissioning assistance and spare parts are included, with service and warranty terms stated in writing.

Frequently Asked Questions

What capacities do Liangpu RO systems cover?

Standard models run from 0.25 T/h to 10 T/h of nominal treated water: 0.25, 0.5, 1, 2, 3, 4, 5, 6, 8 and 10 T/h. 12T, 15T and 30T split-type frames and double-stage systems are also built. Model numbers indicate nominal output; actual output depends on feed-water quality and temperature.

What desalination rate does the RO system achieve?

The standard range is rated at a desalination rate of 95%–99%, with a raw-water inlet pressure of 0.1–0.3 MPa and a membrane inlet pressure of 0.6–1.0 MPa. Suitability for a particular process is confirmed against your feed-water analysis and outlet-water requirement.

What pretreatment is included before the RO membranes?

The standard process is quartz sand filter, activated carbon filter, antiscalant dosing and a cartridge (precision) filter before the high-pressure pump and RO unit. A raw-water pump is added where needed. The final pretreatment is designed from the feed-water analysis.

What power supply do the RO systems use?

The 0.25T/h and 0.5T/h models use 220 V/50 Hz. Models from 1T/h upward use 380 V/50 Hz. Configurations for another voltage or frequency are confirmed on the project datasheet.

Should I choose an integrated or a split-type RO system?

Integrated units arrive on one frame and need a single floor area. Split-type units separate pretreatment from the RO main unit, which suits narrow access or installation in two positions. The 10T/h model is a split-type unit. Compare the listed dimensions with door, lift and stairway clearances.

Which pump and membrane brands are used?

The manufacturer lists Xinjie or Nanfang pumps and Huitong or DowDuPont membranes as options. They are chosen at quotation stage, are not included in every configuration by default, and the brand supplied is stated in the quotation.

Start With These Details

Tell us your country, application, required output per hour or day, water source and available electricity supply. If you do not yet have a water report, say so in your inquiry so we can identify what information is needed next.

Send your RO requirement · Compare water softening · Explore pure-water systems

Standard models from 0.25T/h to 10T/h — dimensions listed above
Configuration selected for feed-water analysis and intended use. Rated output, water quality, electrical supply, packing and service scope confirmed in the project quotation.
Request a Quote
WhatsApp